Fire Fighting & Sprinkler Systems

Turnkey engineering, hydraulic calculation, installation, and bi-annual pressure testing of high-capacity wet risers, yard hydrants, booster pump stations, and automated sprinkler rings across Mumbai & MMR.

Licence: MFS/LA/RF-34/RD-35
NBC 2016 Part 4 & Maharashtra Fire Act
Fire pump station manifold overhaul and valve calibration by Samarth Fire
System Benchmark

Multi-stage booster pump station manifold with synchronized electric, diesel backup, and jockey pressure stabilizers.

What We Offer in Fire Fighting Systems: Turnkey execution from initial design, hydraulic planning, and equipment supply to site fabrication, installation, testing, commissioning, and ongoing maintenance. Under government licence MFS/LA/RF-34/RD-35, our team of 25+ certified technicians installs and maintains wet risers, yard hydrants, booster pumps, automatic sprinklers, and complete pipeline networks across Mumbai and the wider MMR.

WHAT WE OFFER

Turnkey Firefighting System Offerings

From new building pipeline erection to complete pump room overhauls and annual maintenance contracts, we handle every stage of your firefighting water network.

01

Turnkey Supply & Installation

We supply and install complete GI wet and dry risers, yard hydrant ring mains, landing valves, hose boxes, non-kinking hose reels, and automatic sprinkler grids for residential and commercial buildings.

02

Booster Pump Station Automation

We design, erect, and automate multi-pump stations integrating main electric pumps, auxiliary diesel engine backups, and jockey pumps with synchronized automatic cut-in/cut-out control panels.

03

Comprehensive AMC & Upgrades

We provide periodic preventive maintenance contracts, valve gland repacking, pipe descaling, urgent leak repairs, manifold welding overhauls, and modernization of aged or defunct systems.

04

Pressure Testing & Form B Certification

We conduct hydrostatic pressure testing, terrace nozzle flow tests, and issue statutory Form A (new commissioning) and bi-annual Form B maintenance compliance certificates under Maharashtra Fire Services.

REGULATORY AUTHORIZATION

Class D Certified Agency

Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, all high-rise firefighting networks must be installed, audited, and maintained by a licensed agency to remain legally compliant.

Licence No: MFS/LA/RF-34/RD-35
Class Scope: Class D Firefighting
Form B Validity: Active • Jan 2028
COMPANY CATALOGUE OFFERINGS

Firefighting Equipment & Product Range

As listed in our company catalogue, Samarth Fire Protection System supplies, installs, tests, commissions, and services a comprehensive range of firefighting equipment across Mumbai, Navi Mumbai, Thane, and Maharashtra.

01

Fire Hydrants & Landing Valves

Single and double outlet landing valves (63mm gunmetal/stainless steel), instantaneous couplings, standpost columns, draw-out connections, butterfly valves, and non-return valves compliant with IS 5290.

  • • 63mm Oblique & Right-Angle Landing Valves
  • • Yard Hydrants & Standpost Pillars
  • • Four-way & Two-way Fire Brigade Inlets
02

Hoses & Hose Fittings

Reinforced Rubber Lined (RRL) Type A & Type B hoses (15m and 30m lengths), CP hoses, heavy-duty swinging hose reel drums with 30m high-pressure braided tubing, instantaneous male/female couplings, and hose cabinets.

  • • IS 636 Type A & Type B RRL Fire Hoses
  • • 19mm/25mm Swinging Hose Reel Drums
  • • Stainless Steel & Gunmetal Instantaneous Couplings
03

Branches & Nozzles

Short branch pipes with nozzles (IS 903), triple-purpose fog and jet diffuser nozzles, curtain nozzles, revolving nozzles, and specialized foam making branch pipes for industrial fire containment.

  • • Standard Short Branch Pipes (63mm GM/SS)
  • • Triple-Purpose Fog / Jet Shut-off Nozzles
  • • Water Curtain & High-Pressure Diffusers
04

Sprinklers & Accessories

Automatic glass-bulb sprinklers (pendent, upright, horizontal sidewall) rated at 57°C, 68°C, 79°C, and 93°C, flexible stainless steel dropper assemblies, installation alarm valves, retard chambers, and water motor gongs.

  • • UL/FM & IS Approved Quartzoid Bulb Sprinklers
  • • Flexible Dropper Pipes with Ceiling Brackets
  • • Alarm Check Valves & Waterflow Detectors
05

Breathing Apparatus (SCBA) Sets

Self-Contained Breathing Apparatus (SCBA) sets for emergency search, rescue, and hazardous smoke entry. Includes carbon-composite or steel cylinders (300 bar), positive pressure demand valves, full-face silicon masks, and audible alarm whistles.

  • • 30-Minute & 45-Minute Rated Air Cylinders
  • • Ergonomic Backplates with Padded Harnesses
  • • Full Face Masks with Speech Diaphragms
06

Foam Equipment & Accessories

Mechanical foam systems for Class B flammable liquid hazards: mobile foam units (100L / 200L trolleys), in-line variable foam inductors, foam branch pipes (FB 5X / FB 10X), foam pourers, and AFFF / AR-AFFF concentrates.

  • • Mobile Foam Trolley Units (100L / 200L)
  • • In-Line Inductors & Pickup Tubes
  • • Aqueous Film-Forming Foam (AFFF) Concentrates
07

Fire Suppression Systems

Clean agent gas flooding systems (FM-200, Novec 1230 / FK-5-1-12) and CO₂ total flooding systems for high-value assets, server rooms, data centres, UPS rooms, electrical panels, and commercial kitchen hoods.

  • • Server Room Clean Agent Gas Flooding
  • • Electrical Panel Micro-Tubing Suppression
  • • Commercial Kitchen Hood Wet Chemical Systems
08

AMC & System Upgrades

Annual Maintenance Contracts (AMC), periodic pump run testing, pipe leak rectification, replacement of degraded valves, flow rate calibration, and upgrading legacy manual firefighting systems to automated standards.

  • • Scheduled Quarterly / Half-Yearly Servicing
  • • Diesel & Electric Fire Pump Overhauls
  • • Form B Statutory Maintenance Certificates
09

Supply, Installation & Testing

Turnkey execution covering supply, installation, testing, commissioning, and servicing of all fire equipment under licensed engineering supervision with testing records and handover dossiers.

  • • Hydrostatic Pressure Testing of Pipelines
  • • Complete Turnkey Project Execution
  • • Fire Department Compliance Handover
FIELD DOCUMENTATION

On-Site Execution Evidence

Authentic field operations conducted by our certified engineers across residential and commercial towers in Mumbai.

Booster pump station manifold overhaul and valve calibration
Pump Station Overhaul

High-Rise Pump Overhaul

Complete overhaul of booster station: non-return valve replacement, pressure sensor switch calibration, and automated diesel backup testing.

Technician inspecting landing valve and testing water pressure
Landing Valve Test

Hydrostatic Flow Verification

Physical static and running flow measurement at terrace level landing valves to guarantee 3.5 bar minimum operating pressure under NBC 2016.

Corridor hose reel cabinet servicing and maintenance
Corridor First-Response

Hose Box & Valve Servicing

Cabinet hardware alignment, swing-drum gland lubrication, and branch nozzle shut-off validation across multi-wing housing societies.

COMMON QUESTIONS

Frequently Asked Questions

What is the difference between a Wet Riser and a Dry Riser?

A Wet Riser is permanently charged with water under pressure from terrace tanks and booster pumps, ready for instantaneous operation during an emergency. A Dry Riser remains empty during normal conditions and is pressurized by fire brigade pump engines connecting to external inlet breeching valves at ground level.

What pressure must a residential fire hydrant system maintain?

Under National Building Code (NBC) 2016 Part 4 and Maharashtra Fire Prevention standards, high-rise risers must maintain a minimum running pressure of 3.5 kg/cm² (bar) at the topmost hydrant outlet, while withstanding a test pressure of 10 kg/cm² at the basement pump manifold without leakage.

How frequently must fire fighting pumps and hydrants be serviced?

Pumps should undergo automated weekly test-runs to ensure battery starters and diesel fallback engines engage smoothly. Full physical servicing, gland packing inspection, and statutory bi-annual Form B certification must be filed with the municipal fire department twice yearly (January and July).

Need a Firefighting System Installation or Overhaul?

Speak directly with Sameer M. Kangutkar and our certified engineering team for technical evaluations across Mumbai & MMR.