Fire Safety Glossary
Short, plain-English definitions for the fire-safety and compliance terms you'll come across in reports, quotations and conversations with your fire agency.
Terms are grouped by topic. Each links to a fuller guide where one exists.
Compliance & regulation
- Form A
- A certificate issued by a licensed fire agency confirming fire-protection systems have been installed and completed as per the approved plan. Read more in our Form B guide.
- Form B
- A statutory six-monthly certificate (filed in January and July) confirming that installed fire-safety systems remain operational and maintained, required under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006.
- NOC (No Objection Certificate)
- A clearance issued by the fire department confirming no objection to a building's occupation, based on its fire-safety provisions at the time of inspection.
- Class D Licensed Agency
- A category of fire-safety agency licensed by the Directorate of Maharashtra Fire & Emergency Services to install, inspect and certify specific classes of fire-protection systems. Samarth Fire holds licence MFS/LA/RF-34/RD-35.
- Competent authority
- The government body — typically the Directorate of Maharashtra Fire & Emergency Services or local Chief Fire Officer — with legal authority over fire-safety approvals for a given area.
Fire-fighting systems
- Wet riser
- A vertical pipe kept permanently filled with pressurised water so a hose can be connected on any floor without delay. See the full wet riser guide.
- Dry riser
- A vertical pipe left empty until the fire brigade pumps water into it through a ground-level inlet, typically used where a permanent water supply is impractical.
- Landing valve
- The valve and outlet on each floor where a hose connects to the riser pipe.
- Jockey pump
- A small pump that maintains constant line pressure so the larger main and standby pumps don't start and stop for minor pressure drops.
- Booster pump
- A pump that increases water pressure to meet the flow and pressure required at the highest or most distant outlet in a system.
- Yard hydrant / landing valve
- An outdoor hydrant point, typically along a building's perimeter, giving the fire brigade external access to the water supply.
Detection & alarm
- Conventional fire alarm panel
- A panel that reports an alarm by zone (area), not by individual device. See conventional vs addressable.
- Addressable fire alarm panel
- A panel that identifies the exact device in alarm, down to its location, rather than just the zone.
- Manual call point (MCP)
- A break-glass or push-button unit that lets a person manually trigger the fire alarm.
- Heat detector
- A detector that triggers on a rapid rise in temperature or a fixed threshold, often used where smoke detectors would give frequent false alarms (kitchens, boiler rooms).
Extinguishers
- HPT (Hydrostatic Pressure Testing)
- A periodic pressure test of an extinguisher cylinder to confirm it can safely hold its rated pressure, required every 3–5 years depending on type under IS 2190.
- ABC dry powder
- A general-purpose extinguishing agent effective on Class A, B and C fires. See the extinguisher types guide.
- P.A.S.S. technique
- The standard method for operating a portable extinguisher: Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side.
Passive protection
- Fire-rated door (FRD)
- A door assembly tested and certified to resist fire for a specific duration (e.g. 2-hour rated), typically fitted with an automatic door closer to stay shut.
- Fire damper
- A device inside ductwork that closes automatically in a fire to stop flame and smoke spreading through the ventilation system.
- Penetration seal / fire stop
- Fire-resistant sealant or collar used where pipes or cables pass through a fire-rated wall or floor, restoring the barrier's rating at that opening.